[Manuals: MPOD_Information] (647,8 kB)
[Manuals: WIENER-CRATE-MIB] (68,8 kB)
[Manuals: Manual MPOD HV_LV 2.5.3] (3.673,6 kB)
|
Multi Channel LV Modules
Features:
Low Voltage floating modules with 8 channels of 10A / 50W max. with 8V, 16V, 30V, 60V ranges Extremely low noise and ripple: lower than 10mVpp All DC outputs floating with individual return lines, individually sensed Voltage current setting / monitoring for each channel, 12 bit resolution Current monitoring and limiting for each channel, 12 bit resolution Programmable channel parameters (voltages, currents, powers and their limits, ramping, group behavior, etc.) and monitoring via Ethernet (TCP/IP), CANbus and USB Combo interfaces Connectors: 2 x 8 pin high current sub-D, 37 pin sub-D for sense / control Type Channels per module Voltage range MPV 808 8 0V ... 8V MPV 8015 8 0V ... 15V MPV 8030 8 0V ... 30V MPV 8060 8 0V ... 60V
Description:
All Mpod low voltage modules have 8 channels with a maximum of 50W per channel in different voltage ranges. All channels are individually controlled and monitored and have floating, individually sensed outputs. A control input for each channel can be used for Interlock / Inhibit or external hardware ON/OFF. |
Powered by OPENi-CMS 1.1 pre-release © 2004 OPENi-CMS Group.