Overview Multichannel High Voltage-Modules
Features:
HIGH PRECISION series
8 channel HV-PS EHQ 82xx with voltage regulation, Floating GND
2 current measurement ranges
EHQ 82 05x_156 F 500V/15mA 6U, CAN interface REDEL, 20V floating
EHQ 82 10x_805 F 1 kV/8mA 6U, CAN interface REDEL, 20V floating
further Modules available
16 channel HV-PS EHQ F2xx with voltage regulation, Floating GND
2 current measurement ranges
EHQ F2 05x_106 F 500V/15mA 6U, CAN interface REDEL, 20V floating
EHQ F2 10x_805 F 1 kV/8mA 6U, CAN interface REDEL, 20V floating
further Modules available
EHS 8/F 6xxx series
8 channel HV-PS EHS 86xx with voltage and current regulation, Floating GND
EHS 86 05x_156 F 500V/15mA 6U, CAN interface REDEL or SHV
EHS 86 10x_805 F 1kV/8mA 6U, CAN interface REDEL or SHV
EHS 86 20x_405 F 2kV/4mA 6U, CAN interface REDEL or SHV
EHS 86 30x_305 F 3kV/3mA 6U, CAN interface REDEL or SHV
EHS 86 40x_205 F 4kV/2mA 6U, CAN interface REDEL or SHV
EHS 86 60x_105 F 6kV/1mA 6U, CAN interface SHV
16 channel HV-PS EHS F6xx with voltage and current regulation, Floating GND
EHS F6 05x_156 F 500V/15mA 6U, CAN interface REDEL or SHV
EHS F6 10x_805 F 1kV/8mA 6U, CAN interface REDEL or SHV
EHS F6 20x_405 F 2kV/4mA 6U, CAN interface REDEL or SHV
EHS F6 30x_305 F 3kV/3mA 6U, CAN interface REDEL or SHV
EHS F6 40x_205 F 4kV/2mA 6U, CAN interface REDEL or SHV
EHS 8/F 0xxx series
8 channel HV-PS EHS 80xx with voltage and current regulationm, Common GND
EHS 80 05x_156 500V/15mA 6U, CAN interface REDEL or SHV
EHS 80 10x_805 1kV/8mA 6U, CAN interface REDEL or SHV
EHS 80 20x_405 2kV/4mA 6U, CAN interface REDEL or SHV
EHS 80 30x_305 3kV/3mA 6U, CAN interface REDEL or SHV
EHS 80 40x_205 4kV/2mA 6U, CAN interface REDEL or SHV
EHS 80 60x_105 6kV/1mA 6U, CAN interface SHV
16 channel HV-PS EHS F0xx with voltage and current regulation, Common GND
EHS F0 05x_156 500V/15mA 6U, CAN interface REDEL or SHV
EHS F0 10x_805 1kV/8mA 6U, CAN interface REDEL or SHV
EHS F0 20x_405 2kV/4mA 6U, CAN interface REDEL or SHV
EHS F0 30x_305 3kV/3mA 6U, CAN interface REDEL or SHV
EHS F0 40x_205 4kV/2mA 6U, CAN interface REDEL or SHV
EDS F/20 0xx Distribution modules
16 channel Distribution HV-PS EDS Fxxx, Common GND
EDS F0 05x_504 500V/500μA 6U, CAN interface REDEL
EDS F0 05x_105 500V/1mA 6U, CAN interface REDEL
EDS F0 25x_504 2,5kV/500μA 6U, CAN interface REDEL
EDS F0 30x_504 3,0kV/500μA 6U, CAN interface, REDEL
32 channel Distribution HV-PS EDS 20xxx, Common GND
EDS 20 005x_504 500V/500μA 6U, CAN interface REDEL
EDS 20 005x_105 500V/1mA 6U, CAN interface REDEL
EDS 20 025x_504 2,5kV/500μA 6U, CAN interface REDEL
EDS 20 030x_504 2,5kV/500μA 6U, CAN interface, REDEL
VHS 4/C 0xx, VME modules
VME 4 channel HV-PS VHS 4xxx, Common GND
VHS 40 05x_156 500V/15mA VME, single width SHV
VHS 40 10x_805 1kV/8mA VME, single width SHV
VHS 40 20x_405 2kV/4mA VME, single width SHV
VHS 40 30x_305 3kV/3mA VME, single width SHV
VHS 40 40x_205 4kV/2mA VME, single width SHV
VHS 40 60x_105 6kV/1mA VME, double width SHV
VME 12 channel HV-PS VHS Cxxx, Common GND
VHS C0 05x_106 500V/10mA VME, double width SHV, opt. REDEL
VHS C0 10x_605 1kV/6mA VME, double width SHV, opt. REDEL
VHS C0 20x_305 2kV/3mA VME, double width SHV, opt. REDEL
VHS C0 30x_205 3kV/2mA VME, double width SHV, opt. REDEL
VHS C0 40x_155 4kV/1,5mA VME, double width SHV, opt. REDEL
Description:
EHS 8/F 2xxx HIGH PRECISION series
8 or 16 channel with Floating GND, in HIGH PRECISION version
Voltage up to 6000V , current up to 15mA
Extreme high stability of Uout (typ. < 10ppm)
very low temp. drift of Vout in ppm range
low ripple &noise ( typ. < 5 mVss )
Measurement and setting values in floating point single precision
current measurement in 2 ranges:
Resolution of 50 uA in the range Ionom ³ Io ³ 20 uA
and 50 pA in the range of 20 uA ³ Io ³ 0
Protection circuitry
compact (6 HE Euro cassette)
CAN – control , each channel autonomous
low cost system-crates.
EHS 8/F0xxx o. EHS 8/F 6xxx
8 or 16 channel with Floating GND or Common GND, voltage -and current regulation
voltages up to 6kV , current up to 15 mA
low ripple & noise ( < 10mVss up to 4kV , < 50mVss up to 6kV )
Measurement and setting values in floating point single precision
Hardware I/V limit per module
Programmable fast hardware current trip per channel
Flexible group and event handling, e.g. for time delayed trip processing
further protection circuitry
compact (6 HE Euro cassette)
CAN – control , each channel autonomous
low cost system crates for up to 10 modules , Floating - PS (voltage against module-GND and PE ≤ 5 V)
EDS F/20 0xx Distribution module, Common-GND
16 or 32 channels, in different versions with
voltage up to 3 kV and current up to 1 mA
Low ripple and noise ( <10 mVp-p)
Data format measurement and setting values: floating-point single precision
Hardware current trip and voltage limit per module
Flexible Group- and event handling
Protection circuitry e.g. safety loop, ramp down, optional fast
discharge of big load capacity
Very compact (6U cassette)
CAN – control , each channel autonomous
low cost system crates for up to 8 modules with floating PS
( voltage between module-GND and PE<= 25 V)
VME with 4 or with 12 HV-channel, VHS 4/C 0xxx
VME-HV -modules with 4 HV-channel in 1 or 2 Slot-width or with 12 HV-channel in 2 Slot-width
channel with common GND and voltage and current regulation, in various versions with voltages up to 6 kV and current up to 15 mA
Other voltage and current combinations on request, also combined with low voltages (VMS Modules)
Low ripple and noise ( < 10mVP-P up to 4kV)
Measurement and setting values in floating point single precision
Hardware current and voltage limit per module
Programmable fast hardware current trip per channel
Flexible group and event handling, e.g. for time delayed trip processing
Protection circuitry e.g. safety loop , ramp down, optional INHIBIT per channel
Each channel fully remote controllable via VME – interface
|