Logo of the iseg Spezialelektronik GmbH
HomeNewsHardwareSoftwareDownloadRequest
 
Productindex
 
Productcategories
 
Quicklinks
 
Download catalog
 

Overview Multichannel High Voltage-Modules

Features:

EHS 4 / 8 / F  2xxx HIGH PRECISION series

4, 8 or 16 channel with Floating GND, in HIGH PRECISION version
Voltage up to 10kV , current up to 15mA
Extreme high stability of Uout (typ. < 10ppm)
very low temp. drift of Vout in ppm range
low ripple &noise ( typ. < 5 mVp-p ; < 30mVp-p at 10kV)
Measurement and setting values in floating point single precision
current measurement in 2 ranges:
Resolution of 50 uA in the range Ionom ³ Io ³ 20 uA
and 50 pA in the range of 20 uA ³ Io ³ 0
Protection circuitry
compact (6 HE Euro cassette)
CAN – control , each channel autonomous
low cost system-crates.

4 channel HV-PS EHS 42xxx with voltage regulation, 20V Floating GND
2 current measurement ranges

EHS 42 100x_504 10kV/500 uA 6U, CAN interface, Kings 1064-1

8 channel HV-PS EHS 82xx with voltage regulation, 20V Floating GND
2 current measurement ranges

EHS 82 05x_156 500V/15mA 6U, CAN interface, REDEL or SHV
EHS 82 10x_805 1kV/8mA 6U, CAN interface, REDEL or SHV
EHS 82 20x_405 2kV/4mA 6U, CAN interface, REDEL or SHV
EHS 82 30x_305 3kV/3mA 6U, CAN interface, REDEL or SHV
EHS 82 40x_205 4kV/2mA 6U, CAN interface, REDEL or SHV
EHS 82 60x_105 6kV/1mA 6U, CAN interface, SHV
EHS 82 80x_105 8kV/1mA 6U, CAN interface, SHV

16 channel HV-PS EHS F2xx with voltage regulation, 20V Floating GND
2 current measurement ranges

EHS F2 05x_106 500V/15mA 6U, CAN interface, REDEL or SHV
EHS F2 10x_805 1 kV/8mA 6U, CAN interface, REDEL or SHV
EHS F2 20x_405 2kV/4mA 6U, CAN interface, REDEL or SHV
EHS F2 30x_305 3kV/3mA 6U, CAN interface, REDEL or SHV
EHS F2 40x_205 4kV/2mA 6U, CAN interface, REDEL or SHV

further Modules available

EHS 4 / 8 / F  6xxx series

4, 8 or 16 channel with Floating GND, voltage -and current regulation
voltages up to 10kV , current up to 15 mA
low ripple & noise ( < 10mVp-p up to 4kV , < 30mVp-p up to 10kV )
Measurement and setting values in floating point single precision
Hardware I/V limit per module
Programmable fast hardware current trip per channel
Flexible group and event handling, e.g. for time delayed trip processing
further protection circuitry
compact (6 HE Euro cassette)
CAN – control , each channel autonomous
low cost system crates for up to 10 modules , Floating - PS (voltage against module-GND and PE ≤ 5V)

4 channel HV-PS EHS 46xx with voltage and current regulation, Floating GND

EHS 46 100x_504 10kV/500 uA 6U, CAN interface, Kings 1064-1

8 channel HV-PS EHS 86xx with voltage and current regulation, Floating GND

EHS 86 05x_156 500V/15mA 6U, CAN interface, REDEL or SHV
EHS 86 10x_805 1kV/8mA 6U, CAN interface, REDEL or SHV
EHS 86 20x_405 2kV/4mA 6U, CAN interface, REDEL or SHV
EHS 86 30x_305 3kV/3mA 6U, CAN interface, REDEL or SHV
EHS 86 40x_205 4kV/2mA 6U, CAN interface, REDEL or SHV
EHS 86 60x_105 6kV/1mA 6U, CAN interface, SHV
EHS 86 80x_105 8kV/1mA 6U, CAN interface, SHV

16 channel HV-PS EHS F6xx with voltage and current regulation, Floating GND

EHS F6 05x_156 500V/15mA 6U, CAN interface, REDEL or SHV
EHS F6 10x_805 1kV/8mA 6U, CAN interface, REDEL or SHV
EHS F6 20x_405 2kV/4mA 6U, CAN interface, REDEL or SHV
EHS F6 30x_305 3kV/3mA 6U, CAN interface, REDEL or SHV
EHS F6 40x_205 4kV/2mA 6U, CAN interface, REDEL or SHV


EHS 4 / 8 / F  0xxx series

4, 8 or 16 channel with Common GND, voltage -and current regulation
voltages up to 10kV , current up to 15 mA
low ripple & noise ( < 10mVp-p up to 4kV , < 30mVp-p up to 10kV )
Measurement and setting values in floating point single precision
Hardware I/V limit per module
Programmable fast hardware current trip per channel
Flexible group and event handling, e.g. for time delayed trip processing
further protection circuitry
compact (6 HE Euro cassette)
CAN – control , each channel autonomous
low cost system crates for up to 10 modules , Floating - PS (voltage against module-GND and PE ≤ 5 V)
8 channel HV-PS EHS 80xx with voltage and current regulation, Common GND

EHS 40 100x_504 10kV/500 uA 6U, CAN interface, Kings 1064-1

8 channel HV-PS EHS 80xx with voltage and current regulation, Common GND

EHS 80 05x_156 500V/15mA 6U, CAN interface REDEL or SHV
EHS 80 10x_805 1kV/8mA 6U, CAN interface, REDEL or SHV
EHS 80 20x_405 2kV/4mA 6U, CAN interface, REDEL or SHV
EHS 80 30x_305 3kV/3mA 6U, CAN interface, REDEL or SHV
EHS 80 40x_205 4kV/2mA 6U, CAN interface, REDEL or SHV
EHS 80 60x_105 6kV/1mA 6U, CAN interface, SHV
EHS 80 80x_105 8kV/1mA 6U, CAN interface, SHV

16 channel HV-PS EHS F0xx with voltage and current regulation, Common GND

EHS F0 05x_156 500V/15mA 6U, CAN interface, REDEL or SHV
EHS F0 10x_805 1kV/8mA 6U, CAN interface, REDEL or SHV
EHS F0 20x_405 2kV/4mA 6U, CAN interface, REDEL or SHV
EHS F0 30x_305 3kV/3mA 6U, CAN interface, REDEL or SHV
EHS F0 40x_205 4kV/2mA 6U, CAN interface, REDEL or SHV


EDS F/20 0xx Distribution modules

16 or 32 channels, in different versions with
voltage up to 3 kV and current up to 1 mA
Low ripple and noise ( <10 mVp-p)
Data format measurement and setting values: floating-point single precision
Hardware current trip and voltage limit per module
Flexible Group- and event handling
Protection circuitry e.g. safety loop, ramp down, optional fast
discharge of big load capacity
Very compact (6U cassette)
CAN – control , each channel autonomous
low cost system crates for up to 8 modules with floating PS
( voltage between module-GND and PE<= 25 V)
16 channel Distribution HV-PS EDS Fxxx, Common GND

EDS F0 05x_504 500V/500μA 6U, CAN interface, REDEL or SHV
EDS F0 05x_105 500V/1mA 6U, CAN interface, REDEL or SHV
EDS F0 25x_504 2,5kV/500μA 6U, CAN interface, REDEL or SHV
EDS F0 30x_504 3,0kV/500μA 6U, CAN interface, REDEL or SHV

32 channel Distribution HV-PS EDS 20xxx, Common GND

EDS 20 005x_504 500V/500μA 6U, CAN interface, REDEL
EDS 20 005x_105 500V/1mA 6U, CAN interface, REDEL
EDS 20 025x_504 2,5kV/500μA 6U, CAN interface, REDEL
EDS 20 030x_504 2,5kV/500μA 6U, CAN interface, REDEL

EBS 8 / F 0xx Bipolar 4-quadrant modules

8 or 16 channels, in different versions with
voltage up to 3000 V and current up to 1 mA, source and sink
bipolar with zero crossing
Low ripple and noise ( typ. <10 mVp-p)
Data format measurement and setting values: floating-point single precision
Hardware current trip and voltage limit per module
Flexible Group- and event handling
Protection circuitry e.g. safety loop, ramp down, optional fast
discharge of big load capacity
Very compact (6U cassette)
CAN – control , each channel autonomous
low cost system crates for up to 8 modules with floating PS
( voltage between module-GND and PE<= 25 V)

8 channel Bipolar, 4-quadrant HV-PS EBS 8xxx, Common GND

EBS 80 05x_105 500V/1mA 6U, CAN interface, REDEL or SHV
EBS 80 30x_504 3kV/500 uA 6U, CAN interface, REDEL or SHV

16 channel Bipolar, 4-quadrant HV-PS EBS Fxxx, Common GND

EDS F005x_105 500V/1mA 6U, CAN interface, REDEL or SHV
EDS F030x_504 3kV/500uA 6U, CAN interface, REDEL or SHV


VME with 2, 4 or 12 HV-channel, VHS 2 / 4 / C 0xxx

VME-HV -modules with 2 HV channels in 2 Slot-width, 4 HV-channels in 1 or 2 Slot-width or with 12 HV-channels in 2 Slot-width
channelwith common GND and voltage and current regulation, in various versionswith voltages up to 10 kV and current up to 15 mA
Other voltage and current combinations on request, also combined with low voltages (VMS Modules)
Low ripple and noise ( < 10mVp-p up to 4kV; < 30mVp-p up to 10kV)
Measurement and setting values in floating point single precision
Hardware current and voltage limit per module
Programmable fast hardware current trip per channel
Flexible group and event handling, e.g. for time delayed trip processing
Protection circuitry e.g. safety loop , ramp down, optional INHIBIT per channel
Each channel fully remote controllable via VME – interface

VME 2 channel HV-PS VHS 2xxx, Common GND

VHS 20 100x_504 10kV/500uA VME, double width Kings 1064-1

VME 4 channel HV-PS VHS 4xxx, Common GND

VHS 40 05x_156 500V/15mA VME, single width SHV
VHS 40 10x_805 1kV/8mA VME, single width SHV
VHS 40 20x_405 2kV/4mA VME, single width SHV
VHS 40 30x_305 3kV/3mA VME, single width SHV
VHS 40 40x_205 4kV/2mA VME, single width SHV
VHS 40 60x_105 6kV/1mA VME, double width SHV
VHS 40 80x_105 8kV/1mA VME, double width SHV

VME 12 channel HV-PS VHS Cxxx, Common GND

VHS C0 05x_106 500V/10mA VME, double width SHV, opt. REDEL
VHS C0 10x_605 1kV/6mA VME, double width SHV, opt. REDEL
VHS C0 20x_305 2kV/3mA VME, double width SHV, opt. REDEL
VHS C0 30x_205 3kV/2mA VME, double width SHV, opt. REDEL
VHS C0 40x_155 4kV/1,5mA VME, double width SHV, opt. REDEL
Description:

.
 